Products
Catalogs
Special Promotions
News & Events
Applications
Investor Relations
Investor Relations
Technical Support
Careers

Interim report January - June 2010
Biotage AB (publ) - disclosure notice of substantial holding of shares
Biotage appoints Anders Wikström as Vice President of Operations and Anthony Rees as Chief Scientific Officer

Biotage Introduces Resolux™ Peptides Purification HPLC ColumnsNew Isolera™ UV-VIS Flash Purification System delivers widest wavelength range available to chemists (Copy)Biotage Launches New Isolera™ ELS Detector, Helps Isolate Virtually Any CompoundBiotage Introduces Highly-Selective ExploraSep 96-Well Screening Plates based on Molecularly Imprinted Polymers

European Peptide SymposiumBiotage are Gold Sponsors.
5th - 9th September
Copenhagen, DenmarkILMAC 201021st - 24th September
Basel, SwitzerlandAOACAugust 27-28
Orlando, FL27th Montreux Symposium on LC/MS 10th - 12th November
Montreux, SwitzerlandThe 3rd EBF Open Symposium 1st - 3rd December
Barcelona, Spain
 

Flash+ and Samplet Technology

Biotage’s patented Samplets are small, prepacked, sample-loading cartridges. They can be placed into a FLASH+ purification cartridge.

Samplets allow easy preparation of reaction-samples for FLASH+ purification. Simply adsorb the reaction mixture directly onto the Samplet, allow the solvent to evaporate, then insert the dried Samplet into the cartridge for purification. If the dissolution solvent is nonpolar (such as hexane or dichloromethane), simply apply the reaction mixture onto the Samplet and insert the wet Samplet into the cartridge.

This simple approach to sample preparation eliminates the time-consuming rotary evaporation method of adsorbing samples onto loose silica. Numerous Samplets can be prepared in parallel and therefore reduce total sample-preparation time.

Benefits
  • Reduce sample handling
  • Eliminate rotary evaporation and sample concentration
  • Allow simultaneous preparation of multiple samples
  • Eliminate silica exposure
  • Accommodate sample sizes from milligrams to grams
  • Enhance performance
  • Increase loading capacity
  • Provide greater compound retention
  • Create tighter elution bands
  • Increase resolution
  • Get fewer mixed fractions
  • Improve compound purity
  • Increase product yield

Samplet Adsorption Table
Samplets adsorb the following solvent volumes
Samplet Sized For Mass of Silica (g) Mass of C18 (g) Sample Vol (mL)
FLASH 12+™ 0.5 0.6 1
FLASH 25+™ 3.0 4.0 5
FLASH 40+™ 8.0 10 10

 

These methods allow Samplets to function like guard columns, protecting the main cartridge from contamination and improving purification performance.


Figure1:
This comparison of injection techniques shows how Samplets can increase separation performance by improving compound retention, which yields tighter elution bands. This increased resolution improves compound purity and increases product yield.



Conditions

Cartridge: FLASH 40+™S
Eluent: 8:2 Hexane/EtOAc
Flow: 25 mL/min
Load: 500 mg (in 1 mL acetone)


Techniques for Sample Loading with Samplets

For samples that require strong solvents, Samplets provide an alternative to traditional sample-adsorption with loose silica and rotary evaporation.

  • Dissolve a sample in a small amount of strong solvent
  • Apply the sample solution to a Samplet
  • Evaporate the solvent in a fume hood, vacuum oven, or vacuum desiccator
  • Insert the dried Samplet into a FLASH+™ cartridge

For samples soluble in the eluent or in a solvent weaker than the eluent

  • Apply the dissolved sample to the Samplet
  • Load the Samplet into the purification cartridge without drying

Figure 2. Sample-loading diagram

Improved Sample-Loading Technique

  • To the Samplet apply crude samples directly from the reaction vessel – No filtration required
  • Evaporate solvent
  • Insert Samplet into FLASH+ cartridge
  • Perform purification