Initiator™ Eight
The safe, multi-user microwave synthesizer that supports automated method development, analog and multi-gram synthesis.
Compact footprint The Initiator is 50% smaller than its predecessor, fitting easily into any standard fume hood space.
Touch logic control Load and run your samples using a touch screen monitor for simple and intuitive navigation without the need for an external computer, keyboard or mouse.
0.2 to 20 mL without system modifications With the EXP function, use four different vial sizes in any order or combination at any time without system modifications for greater flexibility and direct scale-up of milligrams to grams.
8-position sample bed The 8-position sample bed provides automation to medicinal chemists for rapid optimization of reaction conditions and analog synthesis. The ability to use both large and small vials provides the medicinal chemist flexibility and the ability to rapidly scale-up compounds of interest.
Modular design Easily upgrade from a single-sample manual format to an automated 60-position system.
Enhanced heating performance The new single-mode applicator with the proven Dynamic Field Tuning™ feature offers faster heating of a broader range of solvents.
Best-in-class safety All Biotage microwave synthesizers are designed for safe operation at elevated temperatures and pressures. The Initiator triple-tier safety lock feature ensures maximum operator safety at all times.
1-Point Support™ Biotage’s world-class field service organization serves customers on site to provide the highest quality personalized support.
Heating Process Temperature Temperature increase Pressure range Power range Agitation |
40-250 °C (104-482 °F) 2-5 °C/sec (36-41 °F) 0-20 bar (2 MPa, 290 PSI) 0-300 W at 2.45 GHz Magnetic stirrer |
Sample Processor Reaction vials
Reaction volumes
Rack capacity
Processing Capacity |
2 vial sizes (mL): 0.5-2, 2-5 4 vial sizes (with EXP function) (mL): 0.2-0.5, 0.5-2, 2-5, 10-20 0.5-5 mL 0.2-20 mL (with EXP function) 4/rack (0.2-5 mL) 8/rack (10-20 mL) 40 mL 80 mL (with EXP function)
|
System Requirements Temperature Humidity Electrical supply
Maximum power consumed Cooling
Weight Dimensions
|
18-32 °C (65-90 °F) 20-95% RH EU: 220-240 V, 50 Hz (5 Å) US: 120 V, 60 Hz (10 Å) JP: 100V, 50/60 Hz (10 Å)
1100 VA Pressurized air supply >60 L/min (2.1 cubic feet/min), 2.5 – 4 bar (0.25-0.4 MPa, 36-58 PSI)
64 lb (29 kg) 15.7” x 19.7” x 22.8” W x D x H (400 x 500 x 580mm)
|
Interfaces Touch screen Ethernet LAN |
6.4” complies with IEEE 802.3 (ANSI 8802.3) MII |
Archiving/Backup and Printing |
Via the LAN |
| Upgrade Path |
The Initiator can be upgraded to a 60-position system. Visit Biotage.com or contact your local Biotage sales office for more information. |
|
|