Interim report January - June 2010
Biotage AB (publ) - disclosure notice of substantial holding of shares
Biotage appoints Anders Wikström as Vice President of Operations and Anthony Rees as Chief Scientific Officer
|

Biotage are Gold Sponsors.
5th - 9th September
Copenhagen, Denmark21st - 24th September
Basel, SwitzerlandAugust 27-28
Orlando, FL10th - 12th November
Montreux, Switzerland1st - 3rd December
Barcelona, Spain
|
|
| |
ISOLUTE® SCX-2 Columns
In medicinal chemistry, once the reaction is complete, it is usually necessary to separate the products of the reaction from excess reagents and by-products. This can be performed using ISOLUTE SCX-2 strong cation exchange sorbents. ISOLUTE SCX-2 is a silica-based sorbent with a chemically bonded propylsulfonic acid functional group. The sorbent is used for the isolation of a wide range of basic compounds using both catch & release and scavenging SPE protocols. ISOLUTE SCX-2 is available packed into SPE columns or 96-well plates and in bulk for flow-through or batch applications. Using the catch & release SPE approach, basic target compounds can be isolated from a range of reaction mixtures. ISOLUTE SCX-2 columns and 96-well plates can eb used in a scavenging SPE mode to remove excess reagents, allowing neutral or acidic compounds to pass straight through to the collection vessel.
Chemical Data Base Material: Silica, 50 µm Functional Group: Propylsulfonic acid Capacity: 0.6 meq/g Counter Ion: Proton

Ordering Information ISOLUTE SCX-2 Columns
| Part Number |
Description |
Quantity |
| 532-0050-B |
ISOLUTE SCX-2 500 mg/3 mL |
50 |
| 532-0100-B |
ISOLUTE SCX-2 1 g/3 mL |
50 |
| 532-0050-C |
ISOLUTE SCX-2 500 mg/6 mL |
30 |
| 532-0100-C |
ISOLUTE SCX-2 1 g/6 mL |
30 |
| 456-0200-D |
ISOLUTE SCX-2 2 g/15 mL |
20 |
| 456-0500-E |
ISOLUTE SCX-2 5 g/25 mL |
20 |
| 456-1000-F |
ISOLUTE SCX-2 10 g/70 mL |
16 |
| 456-2000-F |
ISOLUTE SCX-2 20 g/70 mL |
16 |
| 456-5000-J |
ISOLUTE SCX-2 50 g/150 mL |
8 |
| 456-7000-J |
ISOLUTE SCX-2 70 g/150 mL |
8 | ISOLUTE Tab-less Columns for High Throughput Workup
| Part Number |
Description |
Quantity |
| 532-0050-BG1 |
ISOLUTE SCX-2 500 mg/3 mL, tab-less |
50 |
| 532-0100-BG1 |
ISOLUTE SCX-2 1 g/3 mL, tab-less |
50 |
| 532-0050-CG2 |
ISOLUTE SCX-2 500 mg/6 mL, tab-less |
30 |
| 532-0100-CG2 |
ISOLUTE SCX-2 1 g/6 mL, tab-less |
30 | ISOLUTE-96 SCX-2 Fixed-well Plate
| Part Number |
Description |
Quantity |
| 532-0100-P01 |
ISOLUTE-96 SCX-2 100 mg |
1 |
| 532-0500-P01 |
ISOLUTE-96 SCX-2 500 mg |
1 | ISOLUTE Array SCX-2 96-well
| Part Number |
Description |
Quantity |
| 532-0100-T |
ISOLUTE Array SCX-2 100 mg/2 mL |
100 |
1 ISOLUTE tab-less 3 mL columns are compatible with the Mettler Toledo Miniblock® System. 2 ISOLUTE tab-less 6 mL columns are compatible with the ISOLUTE Array-24 System.
|
|
Print page
|
|
|
|
 |
|
|
|