Products
Catalogs
Special Promotions
News & Events
Applications
Investor Relations
Investor Relations
Technical Support
Careers

Interim report January - June 2010
Biotage AB (publ) - disclosure notice of substantial holding of shares
Biotage appoints Anders Wikström as Vice President of Operations and Anthony Rees as Chief Scientific Officer

Biotage Introduces Resolux™ Peptides Purification HPLC ColumnsNew Isolera™ UV-VIS Flash Purification System delivers widest wavelength range available to chemists (Copy)Biotage Launches New Isolera™ ELS Detector, Helps Isolate Virtually Any CompoundBiotage Introduces Highly-Selective ExploraSep 96-Well Screening Plates based on Molecularly Imprinted PolymersBiotage Introduces Highly-Selective AFFINILUTE MIP

European Peptide SymposiumBiotage are Gold Sponsors.
5th - 9th September
Copenhagen, DenmarkILMAC 201021st - 24th September
Basel, SwitzerlandAOACAugust 27-28
Orlando, FL27th Montreux Symposium on LC/MS 10th - 12th November
Montreux, SwitzerlandThe 3rd EBF Open Symposium 1st - 3rd December
Barcelona, Spain
 

Phase Separators

Phase Separators


 
More effiecient than traditional glass separating funnels
Phase separators are a range of ISOLUTE® columns fitted with a selectively permeable, optimized frit material that separates aqueous phase from chlorinated solvents under gravity.

Ready-to-use
There are no moving parts, nothing to prime, its all achieved by hydrophobic/hydrophilic interactions, the cartridges arrive ready to use and are compatible with a wide variety of solvents.

How Phase Separators Work
The compound is partitioned, due to differences in solubility, between two immiscible liquids. The lower organic phase can pass through the frit, the upper aqueous phase physically cannot. There is an automatic cut-off at the organic/aqueous interface.

Reasons customers choose Phase Separators
GREEN: ISOLUTE Phase Separators comply with 6 key principles of Green Chemistry* - prevent excess lab waste, maximize atom economy, facilitate use of safer chemicals and products, and utilize less hazardous chemical synthesis, increase energy efficiency, and minimize the potential for accidents.

COST:
The life-time cost of a glass sep-funnel can average around $150. Also, itis easy to use more solvent than necessary when washing and it is tempting to over-extract. All this means the cost of chlorinated solvent (approx 2-3 washes, of 50-100mL, over 20 uses) is typically higher than it needs to be. Compare this to phase separators. With Phase Separators, there is no cleaning after use. They're disposable. ( av£1.5 or $3 per experiment (overall 10-25% of the cost of using sep funnels).

EFFICIENCY:
Save time, reduce solvent, ISOLUTE Phase Separator tubes are easier to store than glass sep funnels, and are geometrically designed to line up on a FlashVac or rack system, thus enabling the chemist to carry out multiple extractions in parallel. After-use, there is no need to waste valuable time and detergent / solvent, by re-washing, the disposable format allows for a very fast turn around and cycle time for further exactions.

RELIABILITY:
Unlike other competitive products such as hydrophobic filter plates or papers, water will not break through. Biotage dye tests (Figure 1) and also customer testimonial have shown that the ISOLUTE Phase Separators are robust and efficient. ISOLUTE Phase Separators are designed to stand alone, working by unattended operation. The upper aqueous phase cannot pass through the frit, so it is not necessary to manipulate the tap for a clean cut. Just open the lower tap*** and walk away, the cut off is automatic.


Phase Separator Chart


Figure 1. The effectiveness of ISOLUTE Phase Separators
and standard 20 µm PE frits in the separation of aqueous/
dichloromethane mixtures. A suspension or emulsion
may be left overnight without risk of breakthrough.


Representative Procedure
Weigh 10-20 mg of the dye (trisodium 3-hydroxy-4- (4-sulfonato-1-naphthylazo)-2,7 naphthalenedisulfonate),  Figure 2, into a 20 mL glass screw cap vial. Add water (5-7mL) and DCM (5-7mL). Replace screw cap and wrap in lab film. Shake vial to dissolve red dye and thoroughly mix contents. Allow to settle, open vial, pour contents into 25mL ISOLUTE Phase Separator, cited on a FlashVac, using a suitably sized (test tube, minimum 10mL volume) as a collection vessel. Allow time for the 2 layers to separate (1-3 minutes, or leave overnight). The lower layer will be the colorless, translucent DCM layer, and the upper layer will be intensely colored aqueous phase. Open the stopcock under the phase separator and allow draining under gravity. The DCM layer will pass though, leaving the red aqueous layer retained on the separator. Breakthrough of the aqueous layer under gravity will not occur for at least 1 week under normal lab conditions.



Phase Separator Structure



Figure 2: Trisodium 3-hydroxy-4-(4-sulfonato-1-naphthylazo)-
2,7-naphthalenedisulfonate (water soluble) red dye
used in phase separation demonstrations






Ordering Information
Phase Separators

ISOLUTE Columns

Part Number                                       

Description                                                           

Quantity  

120-1903-B

ISOLUTE Phase Separators, 3 mL

100

120-1905-C

ISOLUTE Phase Separators, 6 mL

100

120-1906-D

ISOLUTE Phase Separators, 15 mL

100

120-1907-E

ISOLUTE Phase Separators, 25 mL

100

120-1908-F

ISOLUTE Phase Separators, 70 mL

50

120-1909-J

ISOLUTE Phase Separators, 150 mL

25

ISOLUTE Tab-less Columns for High Throughput Applications

Part Number                                       

Description                                                           

Quantity  

120-1903-BG

ISOLUTE Phase Separators, 3 mL, tab-less

100

120-1905-CG

ISOLUTE Phase Separators, 6 mL, tab-less

100

ISOLUTE Phase Separator Fixed-well Plate

Part Number                                       

Description                                                           

Quantity  

120-1910-P01

ISOLUTE Phase Separators, fixed-well plate

1


ISOLUTE Array Phase Separator Wells

Part Number                                       

Description                                                           

Quantity  

120-1920-T

ISOLUTE Array Phase Separators, 2 mL

100

Print Print page