Biotage and Peptide SynthesisComing soon: Isolera™ Dalton - Flash Chromatography with Integrated Mass IdentificationISOLUTE® Myco SPE columns, a dedicated product for the efficient extraction of mycotoxins from food matricesTLC-to-Step Gradient capability significantly reduces both purification time and solvent useBiotage Releases New Catalog and Technical Guide for Sample Preparation and EvaporationBiotage moving into Mass Directed Flash
 

« Return to Sample Preparation Home Page

ISOLUTE® SLE+
Supported Liquid Extraction

SLE Plates and Columns

ISOLUTE SLE+
Column and Array Formats
Now Available!

Sample Volumes of
200 µL, 400 µL,
1 mL, 2 mL,
5 mL, and 10mL

Request your
FREE Sample!

Replace expensive traditional SPE and labor intensive LLE methods

ISOLUTE SLE+ Supported Liquid Extraction plates and columns offer an efficient alternative to traditional liquid-liquid extraction (LLE) for bioanalytical sample preparation, extracting up to 400 µL aqueous sample. ISOLUTE SLE+ provides high analyte recoveries, eliminate emulsion formation, and cut sample preparation time in half.


Efficient extraction
Supported-liquid extraction mechanism is very efficient, delivering higher analyte recoveries and cleaner extracts than the equivalent LLE method.

No emulsion formation
Emulsions cannot form because the sample and water immiscible extraction solvent are never in direct contact, preventing contamination and maximizing analyte recovery.

Easy to automate
ISOLUTE SLE+ plates and columns provide an easy-to-automate alternative to traditional liquid-liquid extraction. No manual ‘off-line’ steps (capping/mixing/centrifuge/de-capping) required. All procedural steps can be fully automated with no manual intervention necessary. 

Good flow characteristics
The ISOLUTE SLE+ plates and columns are packed with an optimized grade of diatomaceous earth, providing reproducible flow characteristics from well-to-well. Aqueous samples and extraction solvents load evenly across the plate, an important feature for automated sample preparation procedures, where well blockage can lead to loss of valuable samples.

Higher analyte recoveries
High extraction efficiency and elimination of emulsions provide higher analyte recoveries and lower detection limits as seen in Figure 2.
 
SLE+ Plates_Analyte Recovery Comparison
 
Transferable methods
The water immiscible extraction solvents used in LLE can also be used for ISOLUTE SLE+ procedures. Sample pretreatment conditions are also the same, meaning existing LLE methods are easily transferable to ISOLUTE SLE+, reducing method development time.

Features and Benefits

  • Automation friendly procedure improves productivity – no off-line steps required
  • Efficient extraction process maximizes analyte recovery compared to LLE
  • Excellent flow characteristics improve reproducibility
  • Minimal method development. ISOLUTE SLE+ uses the same solvent systems as LLE allowing direct transfer of methods
  • Same clean extracts as LLE – reduced ion suppression leads to improved
    signal to noise
  • Process manually using VacMaster™-96 Sample Processing Manifold or using automated liquid handling systems equipped with a vacuum manifold
  • Fixed well plate format is compatible with all common liquid handling systems

SLE in 96-well Plates
Each plate is made up of 96 individual wells, each containing a modified form of diatomaceous earth.

Options
ISOLUTE SLE+ is available in formats suitable for processing from 200 µL to 10 mL.

Ordering Information

Part Number 
Description Qty
820-0200-P01 ISOLUTE SLE+ 200
Supported Liquid Extraction Plate
1
820-0400-P01 ISOLUTE SLE+ 400
Supported Liquid Extraction Plate
1
820-0200-T ISOLUTE SLE+ 200 2mL Array Wells 200 µL 100
820-0400-T ISOLUTE SLE+ 400 2mL Array Wells 400 µL 100
820-0140-C ISOLUTE SLE+ 1 mL Sample Volume 1 mL 30
820-0290-D ISOLUTE SLE+ 2 mL Sample Volume 2 mL 20
820-0690-E ISOLUTE SLE+ 5 mL Sample Volume 5 mL 20
820-1420-F ISOLUTE SLE+ 10 mL Sample Volume 10 mL 16
German Flag Italian FLag
2011 Analytical Sample Preparation Catalog
2013 Cat Thumbnail_.jpg
eCatalog Button
eCatalog Button

Application Database

View the SLE+ Demonstration Video
SLE+video.jpg
 
Related Information
Downloads
PDF Tech Note
PDF SLE+ User's Guide
PDF Chemistry
Data Sheet
PDF SLE+ Method Selection Guide
PDF SLE+ Columns and
Plates Instruction Card
Conference Talks
PDF MPI Research, Revisiting Tradidional Liquid-Liquid Techniques using SLE

Request Literature

Print Print page