Products
Catalogs
Special Promotions
News & Events
Applications
Investor Relations
Investor Relations
Technical Support
Careers

Interim report January - June 2010
Biotage AB (publ) - disclosure notice of substantial holding of shares
Biotage appoints Anders Wikström as Vice President of Operations and Anthony Rees as Chief Scientific Officer

Biotage Introduces Resolux™ Peptides Purification HPLC ColumnsNew Isolera™ UV-VIS Flash Purification System delivers widest wavelength range available to chemists (Copy)Biotage Launches New Isolera™ ELS Detector, Helps Isolate Virtually Any CompoundBiotage Introduces Highly-Selective ExploraSep 96-Well Screening Plates based on Molecularly Imprinted PolymersBiotage Introduces Highly-Selective AFFINILUTE MIP

European Peptide SymposiumBiotage are Gold Sponsors.
5th - 9th September
Copenhagen, DenmarkILMAC 201021st - 24th September
Basel, SwitzerlandAOACAugust 27-28
Orlando, FL27th Montreux Symposium on LC/MS 10th - 12th November
Montreux, SwitzerlandThe 3rd EBF Open Symposium 1st - 3rd December
Barcelona, Spain
 

EVOLUTE® CX  New Column Configurations!
Drop down for Ordering Information

Click here to request a FREE SAMPLE.
 
EVOLUTE_CX_Image

Mixed-mode Selectivity, Generic Methodology
and Efficient Extraction

EVOLUTE® CX mixed-mode resin-based SPE sorbent extracts a wide range of basic analytes from biological fluids and other aqueous matrices using a generic procedure which minimizes method development time. EVOLUTE CX removes matrix components such as proteins, salts, non-ionizable interferences and phospholipids, delivering cleaner extracts with reproducible recoveries for accurate quantitation.

• Removal of proteins, salts, non-ionizable interferences and phospholipids
• Minimal ion suppression
• 3 times higher signal intensity in LC-MS/MS
• Fast, simple generic methodology
• High, reproducible recoveries for a wide range of basic drugs 

EVOLUTE CX sample preparation products are available in a range of standard configurations.

High selectivity provides ultra-clean extracts
The mixed-mode sorbent chemistry and optimized pore size minimizes retention of high molecular weight matrix components present in the biological fluid samples (Figure 1). The interferences including proteins, salts, non-ionizable molecules and phospholipids are removed during the interference elution step, thereby ensuring extremely clean extracts for LC-MS/MS analysis (Figures 2a and 2b).


EVOLUTE_CX_Fig1
Figure 1. The combination of optimized pore structure and additional interference elution steps using mixed-mode sorbent chemistry guarantees extremely clean extracts.

CX Total Ion Sup
Figure 2a. Total ion suppression measured by FIA analysis. LC-MS/MS signal (m/z 195>138) for spiked plasma, compared to spiked mobile phase. EVOLUTE gives 3 times higher s/n than other resin-based products.


Ion Supression EVOLUTE CX
Figure 2b. Chromatographic ion suppression of five basic drugs. LC-MS/MS signal (342>116) for spiked plasma compared to spiked mobile phase.

Simple, fast method development
EVOLUTE CX uses a single generic methodology suitable for a wide range of basic drugs.

High analyte recoveries
EVOLUTE CX has a water-wettable surface to promote robust, reliable sample preparation. The combination of robust polymer chemistry, uniform coverage of sulfonic acid (SO3-) groups and optimum exchange capacity provide greater than 85% recovery for a wide range of basic drugs.

Excellent flow characteristics
Narrow particle size distribution provides consistent flow characteristics for a variety of sample matrices. Optimized packing techniques eliminate channelling, which can lead to analyte breakthrough.

Batch-to-batch reproducibility
The surface characteristics of each batch of EVOLUTE CX are quality controlled and tested to ensure consistency.

Bioanalysis - EVOLUTE CX 30 µm 
Biotage offers a range of EVOLUTE CX columns and 96-well plates optimised for bioanalytical sample preparation. Request Chemistry Data Sheet TN139 for more details.

Forensic, clinical and environmentlal applications - EVOLUTE CX 50µm
EVOLUTE CX is also available in larger SPE formats suitable for the larger sample volumes and more viscous matrices common in forensic, clinical, food and environmental applications. Request Chemistry Data Sheet TN141 for more details.




Ordering Information

 

EVOLUTE CX Fixed Well Plate

Part Number 

Description  

Quantity  

601-0010-P01

EVOLUTE CX 10 mg Fixed Well Plate

1

601-0025-P01

EVOLUTE CX 25 mg Fixed Well Plate

1

EVOLUTE Array CX Loose Wells

Part Number  

Description                           

Quantity  

601-0010-R

EVOLUTE Array CX 10 mg/1 mL wells

100

601-0025-R

EVOLUTE Array CX 25 mg/1 mL wells

100

Pre-assembled EVOLUTE Array plates are available.
To order, add the suffix P to equivalent loose well part number.

EVOLUTE Array Accessories

Part Number

Description   

Quantity

120-6000-P01

EVOLUTE Array base plate

1

120-1200

Strip of 8 base plate sealing plugs*

50

120-1201

Luer adaptors (fits standard sample processing manifold)

25

120-1202

Well removing tool*

1

*Required when processing a partially populated EVOLUTE Array CX plate.


EVOLUTE CX 1 mL SPE Columns

Part Number

Description

Quantity

601-0001-A

EVOLUTE CX 10 mg/1 mL columns

100

601-0002-A

EVOLUTE CX 25 mg/1 mL columns

100



EVOLUTE CX 1 mL SPE (Tab-less) Columns

Part Number 

Description  

Quantity  

601-0001-AG

EVOLUTE CX 10 mg/1 mL Tab-less SPE columns

100

601-0002-AG

EVOLUTE CX 25 mg/1 mL Tab-less SPE columns

100


NEW! EVOLUTE CX 50 µm Columns

Part Number

Description

Quantity

611-0005-B

EVOLUTE CX 50 µm 50 mg/3 mL
SPE columns 

50

611-0010-B

EVOLUTE CX 50 µm 100 mg/3 mL
SPE columns

50

611-0010-H

EVOLUTE CX 50 µm 100 mg/10 mL
SPE columns(H)1

50

611-0020-B

EVOLUTE CX 50 µm 200 mg/3 mL
SPE columns

50

611-0020-C

EVOLUTE CX 50 µm 200 mg/6 mL
SPE columns

30

611-0050-C

EVOLUTE CX 50 µm 500 mg/6 mL
SPE columns

30


1 100 mg/10 mL (H) columns have the same sorbent bed dimensions as a 3 mL column, but with an extended reservoir for loading sample volumes up to 10 mL in one aliquot.

Click here to download Material Data Safety Sheet

Print Print page