Products
Catalog
Application Database
Webinars
Videos
Investor Relations
Investor Relations
Technical Support
Careers
Demo Instrument Sale

Biotage AB launches share buy-back
Resolutions at the Annual General Meeting in Biotage AB on April 25, 2013
Interim report January - March 2013

Biotage and Peptide SynthesisComing soon: Isolera™ Dalton - Flash Chromatography with Integrated Mass IdentificationISOLUTE® Myco SPE columns, a dedicated product for the efficient extraction of mycotoxins from food matricesTLC-to-Step Gradient capability significantly reduces both purification time and solvent useBiotage Releases New Catalog and Technical Guide for Sample Preparation and EvaporationBiotage moving into Mass Directed Flash
 
« Return to Sample Preparation Home Page


rule
EVOLUTE®
» EVOLUTE EXPRESS EVOLUTE CX
» EVOLUTE ABN » EVOLUTE WAX
» EVOLUTE AX » EVOLUTE WCX
rule
Evolute CX

Request a Sample
Benefits
  • Removal of proteins, salts, non-ionizable interferences
    and phospholipids
  • Minimal ion suppression
  • 3 times higher signal intensity
    in LC-MS/MS
  • Fast, simple generic methodology
  • High, reproducible recoveries for a wide range of basic drugs

Mixed-mode selectivity, generic methodology
and efficient extraction

EVOLUTE CX mixed-mode resin-based SPE sorbent extracts a wide range of basic analytes from biological fluids and other aqueous matrices using a generic procedure which minimizes method development time. EVOLUTE CX removes matrix components such as proteins, salts, non-ionizable interferences and phospholipids, delivering cleaner extracts with reproducible recoveries for accurate quantitation.

EVOLUTE CX sample preparation products are available in a range of standard configurations.

High selectivity provides ultra-clean extracts
The mixed-mode sorbent chemistry and optimized pore size minimizes retention of high molecular weight matrix components present in the biological fluid samples (Figure 1). The interferences including proteins, salts, non-ionizable molecules and phospholipids are removed during the interference elution step, thereby ensuring extremely clean extracts for LC-MS/MS analysis (Figures 2a and 2b).

EVOLUTE_CX_Fig1
Figure 1 The combination of optimized pore structure and additional interference elution steps using mixed-mode sorbent chemistry guarantees extremely clean extracts.

CX Total Ion Sup
Figure 2a Total ion suppression measured by FIA analysis. LC-MS/MS signal (m/z 195>138) for spiked plasma, compared to spiked mobile phase. EVOLUTE gives 3 times higher s/n than other resin-based products.

Ion Supression EVOLUTE CX
Figure 2b Chromatographic ion suppression of five basic drugs. LC-MS/MS signal (342>116) for spiked plasma compared to spiked mobile phase.

Simple, fast method development
EVOLUTE CX uses a single generic methodology suitable for a wide range of basic drugs.

High analyte recoveries
EVOLUTE CX has a water-wettable surface to promote robust, reliable sample preparation. The combination of robust polymer chemistry, uniform coverage of sulfonic acid (SO3-) groups and optimum exchange capacity provide greater than 85% recovery for a wide range of basic drugs.

Excellent flow characteristics
Narrow particle size distribution provides consistent flow characteristics for a variety of sample matrices. Optimized packing techniques eliminate channelling, which can lead to analyte breakthrough.

Batch-to-batch reproducibility
The surface characteristics of each batch of EVOLUTE CX are quality controlled and tested to ensure consistency.

Bioanalysis - EVOLUTE CX 30 µm
Biotage offers a range of EVOLUTE CX columns and 96-well plates optimised for bioanalytical sample preparation.

Forensic, clinical and environmentlal applications - EVOLUTE CX 50µm
EVOLUTE CX is also available in larger SPE formats suitable for the larger sample volumes and more viscous matrices common in forensic, clinical, food and environmental applications.

Ordering Information

Part Number  Description   Qty
EVOLUTE CX Fixed Well Plate
601-0010-PX01 EVOLUTE EXPRESS CX 10 mg Fixed Well Plate 1
601-0030-PX01 EVOLUTE EXPRESS CX 30 mg Fixed Well Plate 1
EVOLUTE Array CX Loose Wells
601-0010-R EVOLUTE Array CX 10 mg/1 mL wells 100
601-0025-R EVOLUTE Array CX 25 mg/1 mL wells 100
Pre-assembled EVOLUTE Array plates are available.
To order, add the suffix P to equivalent loose well part number.
EVOLUTE Array Accessories
120-6000-P01 EVOLUTE Array base plate 1
120-1200 Strip of 8 base plate sealing plugs* 50
120-1201 Luer adaptors (fits standard sample processing manifold) 25
120-1202 Well removing tool* 1
*Required when processing a partially populated EVOLUTE Array CX plate.
EVOLUTE CX 1 mL SPE Columns
601-0001-A EVOLUTE CX 10 mg/1 mL columns 100
601-0002-A EVOLUTE CX 25 mg/1 mL columns 100
EVOLUTE CX 1 mL SPE (Tab-less) Columns
601-0001-AG EVOLUTE CX 10 mg/1 mL Tab-less SPE columns 100
601-0002-AG EVOLUTE CX 25 mg/1 mL Tab-less SPE columns 100
EVOLUTE CX 50 µm Columns
611-0005-B EVOLUTE CX 50 µm 50 mg/3 mL SPE columns
50
611-0010-B EVOLUTE CX 50 µm 100 mg/3 mL SPE columns 50
611-0010-H EVOLUTE CX 50 µm 100 mg/10 mL
SPE columns(H)1
50
611-0020-B EVOLUTE CX 50 µm 200 mg/3 mL SPE columns 50
611-0020-C EVOLUTE CX 50 µm 200 mg/6 mL SPE columns 30
611-0050-C EVOLUTE CX 50 µm 500 mg/6 mL SPE columns 30
1 100 mg/10 mL (H) columns have the same sorbent bed dimensions as a 3 mL column, but with an extended reservoir for loading sample volumes up to 10 mL in one aliquot.
Print Print page