Biotage® Isolera™ Spektra One and Four
Flash Purification System
|
Key Features
- TLC-to-Step gradient
- Gradient Optimization
- Real-time PDA scanning
- 2D and 3D spectral analysis
- Optimized for Biotage®
SNAP Ultra cartridges
- λ-All detection
- Baseline correction
- Run counter
|
 |

Now even more flexibility and capability
Need to hold a gradient to improve a separation?
It is now possible with a new Isocratic Hold button.
Need to collect a large volume of a single eluting compound?
A new fraction collector bypass feature provides collection of any volume in any clean collection vessel, saving fraction capacity.
Need to multi-task?
Monitor the purification from your office and you can advance fractions, use the Isocratic hold feature, monitor solvent and waste levels, pause the purification run, just to name a few.

Advanced, intelligent features enable better, faster purification
The Biotage Isolera flash purification family is designed to help purify synthesis reaction mixtures, natural product extracts, and other mixes of organic compounds requiring separation and purification. Two systems are available in several configurations providing purification of milligrams to >150 g.
Biotage Isolera Spektra is available in a single cartridge base model, the Biotage Isolera Spektra One, and a 4-cartridge configuration, the Biotage Isolera Spektra Four, which is ideal for multi-user or high-throughput laboratories.
Achieve up to 30% solvent savings with Gradient Optimization “GO”
Step-gradients can be short and powerful providing separations for one or more compounds but can be challenging to develop and optimize. Isolera Spektra provides gradient optimization through new, patent-pending TLC-to-Step Gradient technology. Using solvent and TLC Rf values, Isolera Spektra builds a gradient to separate all the compounds (up to 6) in the sample. This new technology will also provide cartridge selection guidance based on the cartridge loading capacity and purification speed. The step gradient can also be used to isolate a targeted compound reducing run time and solvent use further.

Figure 1.Using a TLC-to-Step gradient simulation, a 3-component sample was purified using a Biotage® SNAP HP-Sil 10 g cartridge in less than 9 CV. At a flow rate of 12 mL/min the actual run time was about 9 minutes and used 130 mL of solvent.
Improve fraction and compound purity with λ-All detection and PDA spectral analysis
New PDA scanning and λ-All technology detects any UV absorbing compound eluting from a flash cartridge while measuring and displaying each eluting compound’s individualUV spectrum. Combined with novel baseline rise correction,yield losses to improper wavelength selection and large fraction volumes are no longer a concern. The PDA spectra can be reviewed and used to determine fraction purity eliminating the need for post-flash purity analysis.

Figure 2. All spectra are stored and are reviewable in the Results tab. The 2D data can be used to verify peak UV maxima and also peak purity just by moving a cursor over the peak or area of interest. If the spectrum remains consistent during the scan the fraction is pure. The purity data eliminates using TLC to determine which fractions contain pure compound and which tubes can be combined, which can save up to 1.5 hours a day in fraction analysis.
Elute complex samples with the Quatro-binary gradient
Use up to four solvents in a single gradient to easily purify samples with diverse polarity. With Quatro-binary gradient capability traditional binary gradients with a limited polarity range can be adjusted to elute very lipophilic and highly polar compounds within a single purification.Or compound solubility during the separation by adding a constant amount of a co-solvent, acid, or base with the Isolera's advanced pump.
Maintain compound solubility with a ternary co-solvent
Isocratically pump a third solvent into any binary gradient to help maintain compound solubility eliminating potential over-pressure issues caused by precipitating compounds.
Enhance productivity with on-the-fly editing
Biotage Isolera methods can easily be edited either in front of the Isolera or from the comfort of your office. Edit the gradient (click & drag points AND segments), flow rate, collection volume, fraction wavelengths and modes, and add more collection racks if you need to – all while the run is in progress. Gradient changes can now be made with a simplified graphical interface or through a table layout.
Achieve superior purification with Biotage flash cartridges
The Biotage Isolera Spektra One and Isolera Spektra Four systems can use various styles including Biotage SNAP and Biotage® SNAP Ultra with silica masses from 5 to 750 g.
Additional features:
- Largest integrated fraction capacity
- Quatro-binary Gradient – use up to four solvents in a single gradient
- Isocratic co-solvent – increase compound solubility and recovery
- Default Methods – simplify method creation
- On-the-fly editing – modify purification runs in progress
- Biotage SNAP cartridges – increase loading capacity and improve compound separations.
- Add an auxiliary detector – use other detectors such as the Biotage Isolera ELSD-1080
- An assortment of Biotage SNAP cartridges is included with the Isolera system

Specifications
| Solvent delivery |
Two constant volume (3-mL) electric HPFC pumps |
| Flow rate |
1 – 200 mL/min |
| Pressure limit |
145 psi (10 bar)
|
| UV Detection |
Choice of variable wavelength (200–400 nm), fixed (254 nm), or UV-VIS (200–800 nm) detectors
|
| Flow cell path length |
0.3 mm
|
| UV collection modes |
Single/dual/λ-All wavelengths (variable UV and UV-VIS) |
| Fractionation modes |
Volume, threshold, threshold with volume, low slope, medium slope, custom slope
|
| Collection vessels |
Test tubes (13, 16, 18, and 25 mm) and bottles (120 mL, 240 mL, and 480 mL) |
| Power |
100 – 240 VAC, 50/60 Hz, 4.0 A
|
System control and data management |
On-board computer with 10.4” diagonal touch-screen interface
|
Dimensions (W x H x D) |
355 mm (14”) x 596 mm (23.5”) x 497 mm (19.6”) (single bed) 565 mm (22”) x 596 mm (23.5”) x 497 mm (19.6”) (expanded bed) |
| Weight |
30-35 kg (66-77 lb) |
Ordering information
The Isolera Spektra One and Isolera Spektra Four systems are available in eight different configurations:
| Part Number |
Description |
| Biotage Isolera One |
| ISO-1SF |
with fixed 254 nm wavelength detector and single fraction collector bed |
| ISO-1SV |
with variable 200-400 nm wavelength detector and single fraction collector bed |
| ISO-1SW |
with UV-VIS 200-800 nm wavelength detector and single fraction collector bed |
| ISO-1EF |
with fixed 254 nm wavelength detector and expanded fraction collector bed |
| ISO-1EV |
with variable 200-400 nm wavelength detector and expanded fraction collector bed |
| ISO-1EW |
with UV-VIS 200-800 nm wavelength detector and expanded fraction collector bed |
| Biotage Isolera Four |
| ISO-4SF |
with fixed 254 nm wavelength detector and single fraction collector bed |
| ISO-4SV |
with variable 200-400 nm wavelength detector and single fraction collector bed |
| ISO-4SW |
with UV-VIS 200-800 nm wavelength detector and single fraction collector bed |
| ISO-4EF |
with fixed 254 nm wavelength detector and expanded fraction collector bed |
| ISO-4EV |
with variable 200-400 nm wavelength detector and expanded fraction collector bed |
| ISO-4EW |
with UV-VIS 200-800 nm wavelength detector and expanded fraction collect |
| Biotage Isolera Spektra |
| ISO-SPK |
Isolera Spektra Package |
| SER-SPKUPG |
Isolera Spektra Upgrade |
| Accessories |
| 412019 |
Leak Detector System Standard Bed |
| 412062 |
Leak Detector System Extended Bed |
| 411789 |
Test tube rack, 13 x 100 mm, 4/pk |
| 411790 |
Test tube rack, 16 x 100 mm, 4/pk |
| 411791 |
Test tube rack, 16 x 150 mm, 4/pk |
| 411792 |
Test tube rack, 18 x 150 mm, 4/pk |
| 411793 |
Test tube rack, 25 x 150 mm, 4/pk |
| 411794 |
Bottle rack, 120 mL, 4/pk |
| 411934 |
Bottle rack, 240 mL, 1/pk |
| 411935 |
Bottle rack, 480 mL, 1/pk |
| 411926 |
Expanded bed upgrade
|
| FIV-VLV-1000 |
Injection valve |
| 411081 |
Injection valve to Biotage SNAP cartridge adapter |
| ISO-ELDS-1080 |
Biotage Isolera ELSD |
| |
|