For research use only. NOT for use in diagnostic procedures.
This application note describes the extraction of a panel of three phosphatidylethanol (PEth) alcohol biomarkers from human whole blood using ISOLUTE® SLE+ Supported Liquid Extraction plates prior to LC/MS-MS analysis. The simple sample preparation procedure delivers clean extracts and analyte recoveries greater than 60% with RSDs lower than 10% for all analytes, with reduced levels of phospholipids to improve extract cleanliness and analyte sensitivity. Linearity of greater than 0.999 is achieved for all analytes from 0.5–5000 ng/mL.ISOLUTE® SLE+ Supported Liquid Extraction plates offer an efficient alternative to traditional liquid-liquid extraction (LLE) for bioanalytical sample preparation, providing high analyte recoveries, no emulsion formation, and significantly reduced sample preparation.
Phosphatidylethanol 16:0, Phosphatidylethanol 16:0/18:1 and Phosphatidylethanol 16:0/18:2
Phosphatidylethanol 16:0/18:1 – D5
ISOLUTE® SLE+ 400 µL Sample Capacity Plate, Part Number 820-0400-P01
Add 10 µL of a 250 pg/µL ISTD solution (in H2O:isopropanol, 1:1, v/v) to 100 µL of human whole blood (to give a final concentration of 25 ng/mL).
Add a further 100 µL of H2O:MeCN (80:20 v/v). Mix thoroughly.
Load 200 µL of pretreated whole blood onto each ISOLUTE® SLE+ well. Ensure that the sample covers the entire area of the ISOLUTE SLE+ top frit. Using a Biotage® PRESSURE+96 Positive Pressure Manifold, apply a pulse of pressure to load samples onto the sorbent. Wait 5 minutes for the sample to equilibrate on the sorbent.
Apply an aliquot of ethyl acetate:isopropanol (95:5, v/v, 700 µL) and allow to flow under gravity for 5 minutes. Apply a second aliquot of ethyl acetate: acetate:isopropanol (95:5, v/v, 700 µL) and allow to flow under gravity for 5 minutes. Apply a final aliquot of ethyl acetate:isopropanol (95:5, v/v, 700 µL). For complete solvent recovery apply a pulse of positive pressure at 10 psi (10–20 seconds).
Collect the eluent in 2 mL volume, 96-well collection plate.
Evaporate extracts at 40 °C, for 30 mins at a flow rate of 20–40 L/min using the Biotage® SPE Dry-96.
Reconstitute in isopropanol (200 µL). Vortex mix. Cover plate with a sealing mat prior to injection.
Shimadzu Nexera x 2 UHPLC
Agilent Poroshell 120, EC-C8, 2.7 µm 2.1 x 50 mm with a guard column of the same chemistry
A: 5 mM ammonium formate (aq) B: Isopropanol
0.3 mL/min
40 °C
5 µL
Table 1. UPLC Gradient.
|
Time (min) |
%A |
%B |
|
0 |
40 |
60 |
|
1 |
0 |
100 |
|
4 |
0 |
100 |
|
4.01 |
40 |
60 |
|
5.5 |
40 |
60 |
Shimadzu 8060 Triple Quadrupole MS using ES interface
3 L/min
5 mL/min
15 L/min
400 oC
300 oC
500 oC
270 kPa
Table 2. MS conditions and retention times for target analytes in positive and negative mode.
|
Analytes MRM T |
ransition |
Collision Energy |
Ion Mode |
|
PEth 16:0 |
675.20 255.25 |
32 |
|
|
(675.20 437.20) |
25 |
||
|
PEth 16:0/18:1 |
701.40 281.35 |
34 - |
|
|
(701.40 437.30) |
24 |
||
|
PEth 16:0/18:2 |
699.40 279.30 |
32 - |
|
|
(699.40 255.30) |
35 |
This simple sample preparation method delivers clean extracts and analyte recoveries mostly greater than 60% with RSDs lower than 10% for all analytes (see Figure 2), and LLOQs below 10 ng/mL for all 3 phosphatidylethanol species. Figure 2. below shows recoveries obtained using 400 µL capacity ISOLUTE® SLE+ plates, when loading 200 µL of pre-treated whole blood sample.
Calibration curve performance was investigated from human whole blood spiked between 0.5–5000 ng/mL. Good linearity was observed for all analytes typically delivering r2 values greater than 0.999. Table 3. details linearity performance and associated LOQ for each analyte loading 200 µL of pre-treated whole blood onto a 400 µL capacity plate. Calibration curves for all analytes are shown in Figure 3.
Table 3. Analyte calibration curve r2 and LOQ performance.
|
Analyte |
r2 |
LLOQ (ng/mL) |
|
PEth 16:0 |
0.9994 |
0.5 |
|
PEth 16:0/18:1 |
0.9993 |
0.5 |
|
PEth 16:0/18:2 |
0.9994 |
5 |
When analyzing blood products, it is important to eliminate interferences caused by phospholipids. Unfortunately, phosphatidylethanol is very similar in structure to phospho- lipids that can reduce sensitivity and quickly lead to the degradation of the LC column and MS system. One of the main aims of this study was to develop a sample preparation method that would allow for good recovery of the phosphatidylethanol species without significant levels of phospholipids being present in the extract. The optimum extraction solvent system identified to achieve this leads to slightly reduced recovery of the three phosphatidylethanol species, however the method sensitivity is such that the required detection limits are exceeded.
In this extraction, underloading of the sample was utilized to further clean up the extraction of phospholipids. Underloading (i.e. loading a lower sample volume than the theoretical capacity of the extraction product) when using whole blood also helps to eliminate possible breakthrough of red blood cells, as well as allowing for the use of more polar elution solvents.
This method provides clean extracts and highly sensitive detection for the analysis of three phosphatidylethanol biomarkers. This method has LOQs of at least 5 ng/mL with the usual cut off being 20 ng/mL.
|
Part Number |
Description |
Quantity |
|
820-0400-P01 |
ISOLUTE® SLE+ 400 µL 96-Well Plate |
1 |
|
PPM-96 |
Biotage® PRESSURE+ 96 Positive Pressure Manifold |
1 |
|
SD-9600-DHS-EU |
Biotage® SPE Dry 96 Sample Evaporator 220/240 V |
1 |
|
SD-9600-DHS-NA |
Biotage® SPE Dry 96 Sample Evaporator 100/120 V |
1 |
|
121-5203 |
Collection Plate, 2 mL Square |
50 |
|
121-5204 |
Pierceable Sealing Mat |
50 |
Literature Number: AN934