  • Location

    A laboratory fume hood with the capacity to handle leakage of solvents and provide suitable airflow to prevent the build-up of flammable vapors.

  • Ambient temperature

    Operating: 15–32 °C (59–90 °F).

    Storage and transportation: -25–60 °C (-13–140 °F).

  • Humidity

    20–95% RH (non-condensing).

  • Altitude

    Operation: up to 2000 m above sea level.

  • Pollution degree

    The system shall be installed in a level 2 environment in accordance with EN 60664-1.

  • Electrical supply

    100–127, 220–240 VAC, 50/60 Hz. Connect only to a grounded outlet.

  • Fuses

    T4A-250 VAC, P/N 411916 (2 required).

  • Max power consumed

    300 VA.

  • Fluid path (wetted) materials

    The wetted parts of the system consist of stainless steel, FFKM, PEEK, PP, PE, FEP, PTFE, silica, carbon fiber filled PTFE, and fused silica, which are not affected by common chromatographic solvents.

  • Weight

    23–25 kg (50–54 lbs.) depending on the system configuration

  • Dimensions

    Footprint: (W x D) 335/550 mm x 393 mm (13.2/21.7” x 15.5”).

    The width depends on using one or two collection trays. Height: 545 mm (21.5”) excluding secondary solvent containment.

  • Interfaces

    15.0” (1024 x 768 px) solvent stable TFT LCD touch screen.

  • Ports

    Ethernet port, 4 USB ports, 2 D-Sub 9-pin ports, and AUX port.

  • Data entry

    Touchscreen or USB connection to mouse/keyboard.

  • Software

    UNIX based Java interface with full on-screen QWERTY keyboard.

  • Certification

    CE and FCC marked. CB and NRTL certified.

  • Solvent supply

    A maximum of 4 x 5 liter reservoirs on the optional secondary solvent containment. Larger reservoirs than 5 liters must be placed elsewhere.

    Note: To be compliant with the secondary containment regulations, do not use containers larger than 4 liters.

  • Rack types

    13 x 100 mm, 16 x 100 mm, 16 x 150 mm, 18 x 150 mm, 25 x 150 mm, 120 mL, 240 mL, and 480 mL.

  • Internal detector wavelength

    200–400 nm (UV) or 198–810 nm (UV-VIS).

    Amplitude range: 0 to 6400 mAU (Absorbance Units); accuracy of ±5 mAU.

  • Pressure range

    0–30 bar (0–3000 kPa; 0–435 psi).

  • Gradient precision

    ±2%.

Resources

Ordering information

Part no.
Name
Pack size
Price
Part no.
SER-SEL-WPL
Name
5 Year Warranty Plan - Biotage® Selekt
Pack size
1
Price
Get a quote
Part no.
SEL-2EV
Name
Biotage® Selekt, Two Channel, Extended Collection Bed, UV Detector
Pack size
1
Price
Get a quote
Part no.
SEL-2EW
Name
Biotage® Selekt, Two Channel, Extended Collection Bed, UV-VIS Detector
Pack size
1
Price
Get a quote
Part no.
SEL-2SV
Name
Biotage® Selekt, Two Channel, Single Collection Bed, UV Detector
Pack size
1
Price
Get a quote
Part no.
SEL-2SW
Name
Biotage® Selekt, Two Channel, Single Collection Bed, UV-VIS Detector
Pack size
1
Price
Get a quote
Part no.
SER-SEL-EXW
Name
Extended Warranty - Biotage® Selekt
Pack size
1
Price
Get a quote
Part no.
SER-SEL-FYMP
Name
First Year Maintenance Plan - Biotage® Selekt
Pack size
1
Price
Get a quote
Part no.
SER-SEL-INSTALL
Name
Installation & Familiarization - Biotage® Selekt Systems
Pack size
1
Price
Get a quote

Related products

Biotage® Selekt Enkel | Small-scale flash chromatography system

Biotage® Selekt Enkel is an automated flash chromatography system for small-scale, routine purification in drug discovery and research labs.

Biotage® Sfär Silica HC | High-capacity prepacked flash column

Biotage® Sfär Silica HC is a high-capacity, prepacked normal-phase column designed for efficient, high-resolution flash purification.

Biotage® Selekt ELSD | Easy detection for flash chromatography

Expand your purification capabilities and easily detect compounds without chromophores in flash chromatography.

Remote access for Biotage® Selekt | Secure flash control

Remotely operate Biotage® Selekt systems with secure connectivity and lab software integration. Monitor status, lock runs, and ensure encrypted access.

Biotage® Liquid Level Sensor | Fash chromatography solvent management

Simplify solvent and waste management in flash chromatography with Biotage® Liquid Level Sensor. Seamlessly integrates with Biotage® Selekt systems.

Biotage® Initiator+ | Reliable, scalable microwave synthesizer

Biotage® Initiator+ offers fast, reproducible microwave synthesis and easily upgrades from manual to 8- or 60-position automation.

Biotage® V10 Touch | Fast and automated evaporation system

Biotage® V-10 Touch is a walk-up, walk-away evaporator that rapidly dries samples from aqueous and organic solvents.

Biotage® Initiator+ Alstra™ | Microwave peptide synthesizer

Biotage® Initiator+ Alstra™ offers fast and efficient microwave peptide synthesis for a wide range of peptides and peptidomimetics.

Get a quote for Biotage® Selekt